Unitron Smart Control remote Bedienungsanleitung Seite 5

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 39
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 4
Unitron TrueFit software instruction guide v2.2
5
software. If the Unitron TrueFit software version being used by the fitter does
not have the same password as the one saved to the hearing instrument, the
fitter will be required to enter the correct code to proceed with the fitting.
Note: Password protection prevents reading of information from a hearing
instrument but does not prevent a fitter from creating a new fitting on that same
device.
Presentation: select the preferred tuning values display (absolute or relative);
select visibility options for CR values; hide or show preparation instructions for
the feedback wizard and the in situ test wizard; select whether or not the
pediatric fitting mode recommendation pop-up box is displayed; and choose
whether or not to maintain the aspect ratio of graphs.
Pediatric Modes: View and / or edit the fitting mode defaults for various
pediatric age ranges using the provided tables. Modify aspects related to fitting
formula, global parameters, hearing instrument options, program settings, and
program options.
Standard Mode: View and / or edit the fitting mode defaults for standard mode
(adults) using the provided tables. Modify aspects related to fitting formula,
global parameters, hearing instrument options, program settings, and program
options.
Reports:
Graphs: select the preferred graph type: Output or Gain. For the Output graph
type, choose from: HL, SPL Real Ear, SPL 2cc, SPL Ear Simulator. For the Gain
graph type, choose from: 2cc, Ear Simulator, Real Ear, Insertion Gain.
Fitting Device:
Communication: fitting device management selects whether the fitting device is
accessible by other programs while using Unitron TrueFit .
NOAHlink: enable/disable the NOAHlink, perform a system check, configure
properties, or start the pairing wizard.
HI-PRO: enable/disable the HI-PRO, perform a system check or configure.
iCube: enable/disable the iCube, perform a system check via USB or wireless
connection, upgrade iCube firmware, or start the iCube pairing wizard.
Sound System:
Sound Output: select either stereo speaker or Aurical.
Calibration: calibrate to ensure media player sound files are presented at the
correct level. Manual calibration uses a sound level meter. Play the calibration
noise and adjust the Unitron TrueFit volume slider and/or Windows volume
slider until you measure 80 dB (A) at the listening position (where the client will
sit). For Automatic calibration start the calibration wizard. This process uses the
hearing instrument to measure and adjust the sound level.
iCube Configuration: opens the iCube configuration section in Preferences. The
screen provides ability to enable/disable the iCube, perform a system check via
USB or wireless connection, upgrade iCube firmware or start the iCube pairing
wizard (i.e., add an iCube).
Accessory Firmware Update: opens a dialog box used to update uDirect
devices
and remote controls. The accessory must be connected to the computer using an
USB cable. After detecting the device, Unitron TrueFit will offer available firmware